Skip to content

WebUI Remote Management ​

This chapter covers how to deploy the WebUI controller and manage an MSST-Net client remotely from a browser.

When to Use It ​

The WebUI controller (msst-net-webui) is suited for:

  • Servers without a desktop environment
  • Devices you want to view and manage remotely from another computer

The WebUI runs on the same device as the client core, connects to the core over local IPC, and then serves the same interface as the desktop edition to the browser over HTTPS.

If you only manage the device in its local terminal (or over SSH) and don't need a browser, the command-line controller msst-net-cli is an alternative: it needs no access password and opens no ports. See Controller.


First Start ​

bash
msst-net-webui

On first start you must set an access password (at least 6 characters). The password is obtained in this order:

  1. The file pointed to by the PASSWORD_FILE environment variable (default /run/secrets/admin_password)
  2. The ADMIN_PASSWORD environment variable
  3. If neither is set, you are prompted to enter and confirm it in the terminal

The password is stored as an Argon2 hash and is not asked for on later starts.

Once it is running, open in your browser:

text
https://<device-address>:18080

The WebUI generates a new self-signed certificate on every start, so the browser will warn that the certificate is untrusted the first time; confirm to continue.


Configuration Files ​

WebUI configuration is stored in ~/.config/msst-net-webui/ (%APPDATA%\msst-net-webui\ on Windows; set MSST_WEBUI_CONFIG_DIR to use another directory, e.g. a volume in a container):

FileDescription
config.tomlListening port and IP allowlist
passwdHash of the access password

Default contents of config.toml:

toml
port = 18080
allowed_cidrs = [
    "127.0.0.0/8",
    "::1/128",
    "10.0.0.0/8",
    "172.16.0.0/12",
    "192.168.0.0/16",
    "fc00::/7",
]

If config.toml exists but cannot be parsed, the WebUI refuses to start instead of falling back to the defaults, so the allowlist is never loosened by accident.

MSST-Net's own virtual networks (172.22.0.0/16, fd22:2222:2222:2222::/64) are not allowed to reach the WebUI by default, even though the default allowlist's 172.16.0.0/12 and fc00::/7 cover them. To allow other devices in MSST-Net, add an entry inside the virtual network explicitly (for example one device's 172.22.x.y/32).

Environment Variables ​

VariableDescription
WEBUI_BINDOverride the listening address (default 0.0.0.0:<port>)
MSST_WEBUI_CONFIG_DIRConfiguration directory
MSST_IPC_PATHSpecify the client core's IPC socket path
PASSWORD_FILE / ADMIN_PASSWORDSource of the access password on first start

Security ​

  • Access password: every page and API requires logging in first; failed logins are answered with a delay to slow down brute-force attempts. A login session lasts 24 hours; after the WebUI restarts you log in again
  • IP allowlist: every request is checked to make sure its source address is within allowed_cidrs
  • HTTPS: all traffic is encrypted
  • Cross-site WebSocket connections are rejected

The IP allowlist can also be changed in the WebUI under Settings → Remote Management.

If you remove the address range the current browser is using, this browser will no longer be able to reach the WebUI.


Feature Differences ​

Compared with the desktop edition, the WebUI edition:

  • Does not support interactive authorization: access requests must be handled on the device itself, otherwise they time out after 60 seconds
  • Supports the rule wizard and permission group management
  • Supports rooms, domain management and diagnostic tools

Read-Only Mode ​

If the system user running the WebUI only has viewer permissions on the client core, the WebUI shows a read-only notice and all modifications are unavailable.

For how to grant admin permissions, see: Controller